Trinzic 815/Trinzic 825 | |
Network Interfaces | • Two 10/100/1000 Base-T Ethernet (LAN ports) |
• One 10/100/1000 Base-T Ethernet (HA port) | |
• One 10/100/1000 Base-T Ethernet (MGMT port) | |
Lights Out Management (LOM) | • One 10/100/1000 Base-T Ethernet LOM port |
• IPMI 2.0 compliant | |
• Supports IPv4 | |
Serial Port | DB-9 (9600/8n1, Xon/Xoff) |
USB Ports | One USB 3.0/2.0 compliant (reserved for future use) |
LCD Panel | NA |
Unit Identification | Front and back |
AC Power Supply | • One internal fixed PSU |
• Input voltage: 100–240 VAC switchable 47–63 Hz | |
• Output power: 350W | |
DC Power Supply | NA |
Chassis Ground | Included (ground lug) |
Disk and Fans | • Three fixed fans |
• One fixed disk drive | |
• System on flash | |
Operating Temperature | • 41°F to 95°F (5°C to 35°C) |
• 5% to 95% relative humidity, non-condensing | |
Storage Temperature | • -40°F to 122°F (-40°C to 50°C) |
• 5% to 95% relative humidity, non-condensing | |
Dimensions and Weight | • Enclosure: 1U, 19 in., rack mountable |
• Height: 44 mm (1.73 in.); 1 rack unit | |
• Width: 441 mm (17.36 in.) | |
• Depth: 522 mm (20.55 in.) | |
• Weight: Approximately 17 lbs (7.71 kg) | |
Rail Kit | Choice of 2-post, up-to-600 mm 4-post, or 600–900 mm 4-post |
Certifications | • Safety: FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, and GOST |
• Environmental: WEEE and RoHS | |
Support | Standard warranty includes 90-day software support with one-year hardware support; upgradable |
Trinzic 1415/Trinzic 1425 | |
Network Interfaces | • Two 10/100/1000 Base-T Ethernet (LAN ports) |
• One 10/100/1000 Base-T Ethernet (HA port) | |
• One 10/100/1000 Base-T Ethernet (MGMT port) | |
• Optional: Four 1GE SFP or 1GE/10GE SFP+ interfaces* | |
Lights Out Management (LOM) | • One 10/100/1000 Base-T Ethernet LOM port |
• IPMI 2.0 compliant | |
• Supports IPv4 | |
Serial Port | DB-9 (9600/8n1, Xon/Xoff) |
USB Ports | One USB 3.0/2.0 compliant (reserved for future use) |
LCD Panel | N/A |
Unit Identification | Front and back |
AC Power Supply | • One hot-swappable PSU |
• Optional second, hot-swappable, redundant PSU | |
• Input voltage: 100–240 VAC switchable, 50–60 Hz | |
• Output power: 600W | |
DC Power Supply | • One hot-swappable PSU |
• Optional second, hot-swappable, redundant PSU | |
• Input voltage: -44V to -65V; 600W | |
Chassis Ground | Included (ground lug) |
Disk and Fans | • Six fixed fans |
• One field-replaceable hard disk | |
• System on flash | |
Operating Temperature | • 41°F to 95°F (5°C to 35°C) |
• 5% to 95% relative humidity, non-condensing | |
Storage Temperature | • -40°F to 122°F (-40°C to 50°C) |
• 5% to 95% relative humidity, non-condensing | |
Dimensions and Weight | • Enclosure: 1U, 19 in., rack mountable |
• Height: 44 mm (1.73 in.); 1 rack unit | |
• Width: 441 mm (17.36 in.) | |
• Depth: 547 mm (21.54 in.) | |
• Weight: Approximately 20 lbs (9.07 kg) | |
Rail Kit | Choice of 2-post, up-to-600 mm 4-post, or 600–900 mm 4-post |
Certifications | • Safety: FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, and EAC |
• Environmental: WEEE and RoHS | |
Support | Standard warranty includes 90-day software support with one-year hardware support; upgradable |
Trinzic 2215/Trinzic 2225 | |
Network Interfaces | • Two 10/100/1000 Base-T Ethernet (LAN ports) |
• One 10/100/1000 Base-T Ethernet (HA port) | |
• One 10/100/1000 Base-T Ethernet (MGMT port) | |
• Optional: Four 1GE SFP or 1GE/10GE SFP+ interfaces* | |
Lights Out Management (LOM) | • One 10/100/1000 Base-T Ethernet LOM port |
• IPMI 2.0 compliant | |
• Supports IPv4 | |
Serial Port | DB-9 (9600/8n1, Xon/Xoff) |
USB Ports | One USB 3.0/2.0 compliant (reserved for future use) |
LCD Panel | N/A |
Unit Identification | Front and back |
AC Power Supply | • Two hot-swappable PSUs |
• Input voltage: 100-240 VAC switchable, 50-60 Hz | |
• Output power: 600W | |
DC Power Supply | • Two hot-swappable PSUs |
• Input voltage: -44V to -65V; 600W | |
Chassis Ground | Included (ground lug) |
Disk and Fans | • Six hot-swappable, redundant fans |
• Four hot-swappable, redundant disks RAID-10 | |
• System on flash | |
Operating Temperature | • 41°F to 95°F (5°C to 35°C) |
• 5% to 95% relative humidity, non-condensing | |
Storage Temperature | • -40F to 122F (-40C to 50C) |
• 5% to 95% relative humidity, non-condensing | |
Dimensions and Weight | • Enclosure: 2U, rack mountable |
• Height: 88 mm (3.46 in.); 2 rack units | |
• Width: 441 mm (17.36 in.) | |
• Depth: 547 mm (21.54 in.) | |
• Weight: Approximately 29 lbs (13.15 kg) | |
Rail Kit | Choice of 2-post, up-to-600 mm 4-post, or 600–900 mm 4-post |
Certifications | • Safety: FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, and EAC |
• Environmental: WEEE and RoHS | |
Support | Standard warranty includes 90-day software support with one-year hardware support; upgradable |
Trinzic 4015/Trinzic 4025 | |
Network Interfaces | • Two 10/100/1000 Base-T Ethernet (LAN ports) |
• One 10/100/1000 Base-T Ethernet (HA port) | |
• One 10/100/1000 Base-T Ethernet (MGMT port) | |
• Optional: Four 1GE SFP or 1GE/10GE SFP+ interfaces* | |
Lights Out Management (LOM) | • One 10/100/1000 Base-T Ethernet LOM port |
• IPMI 2.0 compliant | |
Serial Port | DB-9 (9600/8n1, Xon/Xoff) |
USB Ports | Six USB 2.0/1.1 compliant (reserved for future use) |
LCD Panel | NA |
AC Power Supply | • Two hot-swappable, redundant PSUs |
• Input voltage: 100–240 VAC, 50–60 Hz | |
• Output power: 600W | |
DC Power Supply | • Two hot-swappable, redundant PSUs |
• Input voltage: -44V to -65V | |
Disk and Fans | • Four or six (four for AC model, six for DC/NEBS model) hot-swappable, redundant fans |
• Four hot-swappable, redundant disks RAID-10 | |
Operating Temperature | • 41°F to 95°F (5°C to 35°C) |
• 5% to 95% non-condensing | |
Storage Temperature | • -40°F to 122°F (-40°C to 50°C) |
• 10% to 90% non-condensing | |
Dimensions and Weight | • Enclosure: 2U, rack mountable (4-post only) |
• Height: 88 mm (3.46 in.); 2 rack units | |
• Width: 441 mm (17.36 in.) | |
• Depth: 534 mm (21 in.) | |
• Weight: Approximately 29 lbs (13.15 kg) | |
Rail Kit | 4-post |
Certifications | • Safety: FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, and EAC |
• Environmental: WEEE and RoHS | |
Support |
Standard warranty includes 90-day software support with one-year hardware support; upgradable |